Model No. : YD145

Brand : YUKA

Origin : China

Element Serve Life : 6000~8000 Hours

Clapboard : Without Clapboard

Filter Number : 1

Medium Material : Fiberglass

Type : Cartridge Filter

Material : Aluminum Alloy

Housing Serve Lige : 15 Years

Filtration Performance : From 5 μm To 0.01μm

Maxi. Operate Pressure : 1.0mpa

Operate Temperature : 1.5~80ºc

Resistance Corrosion : Inside And Outside

Parts : Dp Indicator, Auto Drain, Sight Glass

Transport Package : Brown Inner Box & Cardboard

Filtration Grade : Medium Filter

Connection : Rc1-1/2"

Efficiency : F9

Diversion Fin Design On Element Top Cap : Less Pressure Loss

Flow Rate : 4.8m³/Min

OEM & ODM Service : Yes

Pressure Loss : About 0.25 Bar

Bleed Valve : Available

Specification: Dimension : 120x110x 477mm

Place of Origin : China

Brand Name : Yuka

Price : Negotiable

Packaging Details : Box Package

Delivery Time : 3-7working days

Payment Terms : L/C,T/T

MOQ : 50pcs

Supply Ability : 300,000pcs/month

Contact Now

Product Description

Air Compressor Accessories-Compressed Air Filter, Refrigerated Air Dryer, auto drain-high quality & cost effective.

The primary reason for using a compressed air filter is to remove contaminate and improve air quality.

Let’s take a look at the different types of air filters and the questions that will help you choose the correct filter.

①Assess the requirements of your application. Different industry require different solution. ③Any specific micron of filtration performance you required?
②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams.
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel)
⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment.

PRODUCT OVERVIEW

Commodity Compressed air filter
Model YD145
Flow rate 7.2m³/min
Element grade 5μm/1μm /0.01μm/0.001mg/m³
Working pressure 143 psi g
Working temperature 1.5~80
Material Aluminum Alloy
Color of housing Red
Trade term EXW & FOB SHENZHEN
Package Internal Box & External Carton
Warranty 15 years for filter housing, 4000-6000 hours under rated working conditions for Filter Element

5 Micron Air Filter Low Pressure Drop

Filter Element Grade

Filtration Grade 5 Micron Air Filter Low Pressure Drop 5 Micron Air Filter Low Pressure Drop 5 Micron Air Filter Low Pressure Drop 5 Micron Air Filter Low Pressure Drop 5 Micron Air Filter Low Pressure Drop 5 Micron Air Filter Low Pressure Drop 5 Micron Air Filter Low Pressure Drop
PF AO AA AX ACS AR AAR
Particle removal (ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm
Outlet oil aerosol concentration (ISO12500-1) 5mg/m³ 0.6mg/m³ <0.01mg/m³ <0.001mg/m³ <0.004mg/m³ - -
Filtration performance of Particle (ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+%
Filtration performance of (ISO12500-1) 50% 80+% 99.9+% 99.99+% - - -
Element spanlife 6000 hours 6000 hours 6000 hours 6000 hours 2000-3000 hours 4000-6000 hours 4000-6000 hours
Precede with Before refrigerated air dryer after air dryer after AO after AA before AX after desiccant dryer after AR
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.

Model Pipe size Flow rates Dimension (mm)
L/S /min scfm W(Width) D (Depth) H (Height) A B C(clearance for housing)
YD017 RC1/2" 16.7 1.0 35.3 89 79 246 40 186 118
YD025 RC3/4" 25.0 1.5 53.0 89 79 246 40 186 118
YD030 RC1/2" 30.0 1.8 63.6 89 79 280 40 220 158
YD035 RC3/4" 33.3 2.0 70.6 89 79 280 40 220 158
YD058 RC3/4" 46.7 2.8 98.9 120 110 377 55 276 195
YD068 RC1" 60.0 3.6 127.1 120 110 377 55 276 195
YD080 RC1" 80.0 4.8 169.5 120 110 477 55 377 290
YD145 RC1-1/2" 120.0 7.2 254.2 120 110 477 55 377 290
YD220 RC2" 200.0 12.0 423.7 162 151 676 64 566 480
YD260 RC2-1/2" 233.3 14.0 494.4 162 151 676 64 566 480
YD330 RC2" 267.2 16.0 564.8 162 151 984 64 875 780
YD360 RC2-1/2" 317.3 19.0 670.7 162 151 984 64 875 780
YD405 RC2-1/2" 367.4 22.0 776.6 200 189 757 78 634 560
YD430 RC3" 467.6 28.0 988.4 200 189 757 78 634 560
YD620 RC3" 620.0 37.2 1313.6 200 189 1012 78 889 780
Technical requirements Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C

Pressure Barg 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 73 87 100 116 131 145 160 174 189 203 219 232
Correction factor 0.38 0.53 0.65 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51


Compressed Air Filter Parts in Detail

YD017-YD035

5 Micron Air Filter Low Pressure Drop

YD058-YD145
5 Micron Air Filter Low Pressure Drop

YD220-YD620

5 Micron Air Filter Low Pressure Drop

Success Cases

5 Micron Air Filter Low Pressure Drop


China 5 Micron Air Filter Low Pressure Drop wholesale

5 Micron Air Filter Low Pressure Drop Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hongrijia Depurate Facility Science & Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)